45
STVZSkW ed 09/08 VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
Combustion parameters.
G20 G30 G31
Supply pressure mbar (mm c.a.) 20 (204) 29 (296) 37 (377)
VICTRIX ZEUS Superior 26 kW I
Gas nozzle diameter mm 5.70 4.10 4.10
Flue ow rate at max heat output kg/h 43 39 43
Flue ow rate at min heat output kg/h 8 7 8
CO
2
at Q. Nom./Min. % 9.40 / 8.90 12.00 / 11.80 10.60 / 10.20
CO at 0% of O
2
at Nom. Q./Min. ppm 200 / 7 670 / 11 270 / 7
NO
X
at 0% of O
2
at Nom. Q./Min.. mg/kWh 50 / 25 188 / 68 69 / 41
Flue temperature at nominal output °C 78 86 79
Flue temperature at minimum output °C 73 82 75
VICTRIX ZEUS Superior 32 kW I
Gas nozzle diameter mm WITHOUT 6.00 6.00
Flue ow rate at max heat output kg/h 52 47 53
Flue ow rate at min heat output kg/h 12 11 12
CO
2
at Q. Nom./Min. % 9.40 / 8.90 12.30 / 11.90 10.50 / 10.30
CO at 0% of O
2
at Nom. Q./Min. ppm 206 / 9 640 / 8 190 / 8
NO
X
at 0% of O
2
at Nom. Q./Min. mg/kWh 50 / 25 188 / 68 69 / 41
Flue temperature at nominal output °C 73 82 74
Flue temperature at minimum output °C 64 72 66