EasyManua.ls Logo

Indel Webasto Marine Isotherm Built-In Series - Page 27

Indel Webasto Marine Isotherm Built-In Series
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
26
The fuse blows. The wrong fuse is being used.
Defecve electronic control
unit.
Check the fuse: see table in secon 5.4.
Replace the electronic control unit.
The compressor is operang
intermiently.
Baery low or electrical cables
in poor condions.
Check wiring condions, examining for
loose connecons, rust or verdigris. If
wiring needs to be replaced, see the
manual for correct sizing. If wiring is in
good condions, check baery funcon
and replace if in poor condion.
The compressor never stops
(correct fridge performance)
Incorrect thermostat
connecon on the electronic
control unit. Thermostat
broken. Condensaon is not
working properly, evaporator
cools but not enough to cause
the thermostat to stop the
compressor.
Rotate the thermostat to o posion. If
the refrigerator connues to funcon,
then there is connuity on the control
unit. Correct the problem on thermostat
connecons (make sure the bridge
is present on C and P and not on C
and T on the electronic control unit).
Rotate the thermostat to o posion.
If the compressor switches o but it is
impossible to regulate temperature,
replace the thermostat or recharge the
cooling system.
The compressor never stops
(poor fridge performance)
Environment very hot +
insucient venlaon or lile
gas in the refrigerant circuit.
Check venlaon. The compressor must
be installed in a well-venlated locaon.
If possible, remove the refrigerator from
the installaon hole. If the refrigerator
operates beer, improve venlaon,
consulng the manual for correct
installaon. If venlaon is instead
opmal, check for the presence of gas
in the system, contacng a specialised
technician.
The freezer compartment
is cold but the refrigerator
is not
Insucient venlaon,
lile gas in the refrigerant
circuit, electrical power not
connuous.
Check venlaon. The compressor must
be installed in a well-venlated locaon.
If possible, remove the refrigerator from
the installaon hole. If the refrigerator
operates beer, improve venlaon,
consulng the manual for correct
installaon. Check electrical connecon
and baery condions. If venlaon is
instead opmal, check for the presence of
gas in the system, contacng a specialised
technician.

Table of Contents

Related product manuals