Indesit Company
29 of 33
Service Manual UK English
FAULT CODES
USER INTERFACE
POWER BOARD
FILTER
FAN
TERMINAL BLOCK
COIL 145 S
COIL 210 S
COIL 210 L
POWER CORD
Hob Status
Codes
Fault Description Service Steps
Step 2 If fault persists, service visit required.
Step 3 Change user interface.
F / c
User interface
overtemperature
Step 1 Advice the user not to put hot pans on control area. W ait until the system cools down.
F / E
User interface
temperature sensor
(NTC) error
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Change user interface.
F / H EEPROM error
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Change user interf ace.
F / J Safety key error
Step1 Asktheusertoswitchthepoweroff andon(trytoresetthesystem).
Step 2 If fault persists, service visit required.
Step 3 Change user interface.
F / L
Light condition error
(keyboard error)
Step 1
Advisetheusertoswitchoff anylighting.
Then switch the power off and on.
(Lights can affect the user interface initial calibration process).
F / t
User interface
temperature sensor
(NTC) error
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Change user interface
Change user interface
.
F / U
Safety key error
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2
Step 3
If fault persists, service visit required.