FAULT CODES
USER INTERFACE
POWER BOARD
FILTER
FAN
TERMINAL BLOCK
COIL 145 S
COIL 210 S
COIL 210 L
POWER CORD
Hob Status
Codes
Fault Description Service Steps
Step 4 If harness OK, change user interface.
Step 5 If fault persists change Power board.
F / 6 Mains zero crossing loss
ƔƔ
Step 1 Ask the user to confirm correct connection to power supply, ensuring link is in place.
Step 2 If external wiring and connection to appliance is correct service visit required.
Step 3 Replace Power board.
Step 4 If fault persists replace filter unit.
F / 7
Induction heater
temperature sensor
(NTC) error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Check heater temperature sensor (NTC) connections. If OK replace Power board.
F / 8
Induction heater
temperature sensor
(NTC) error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Check heater temperature sensor (NTC) connections. If OK replace Power board.
F / 9 Heater overvoltage fault
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Replace Power board.
F / A Safety key error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Change user interface.
F / C Safety key error
Ɣ
Step 1
Ask the user to switch off any halogen lights and clean the glass surface.
Then switch the power off and on (try to reset the system).