EasyManua.ls Logo

Indesit VIX644CE - Fault Code F;6 - Mains Zero Crossing Loss; Fault Code F;7 - Induction Heater Temperature Sensor Error; Fault Code F;8 - Induction Heater Temperature Sensor Error; Fault Code F;9 - Heater Overvoltage Fault

Indesit VIX644CE
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indesit Company
28 of 33
Service Manual UK English
FAULT CODES
USER INTERFACE
POWER BOARD
FILTER
FAN
TERMINAL BLOCK
COIL 145 S
COIL 210 S
COIL 210 L
POWER CORD
Hob Status
Codes
Fault Description Service Steps
Step 4 If harness OK, change user interface.
Step 5 If fault persists change Power board.
F / 6 Mains zero crossing loss
ƔƔ
Step 1 Ask the user to confirm correct connection to power supply, ensuring link is in place.
Step 2 If external wiring and connection to appliance is correct service visit required.
Step 3 Replace Power board.
Step 4 If fault persists replace filter unit.
F / 7
Induction heater
temperature sensor
(NTC) error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Check heater temperature sensor (NTC) connections. If OK replace Power board.
F / 8
Induction heater
temperature sensor
(NTC) error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Check heater temperature sensor (NTC) connections. If OK replace Power board.
F / 9 Heater overvoltage fault
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Replace Power board.
F / A Safety key error
Ɣ
Step 1 Ask the user to switch the power off and on (try to reset the system).
Step 2 If fault persists, service visit required.
Step 3 Change user interface.
F / C Safety key error
Ɣ
Step 1
Ask the user to switch off any halogen lights and clean the glass surface.
Then switch the power off and on (try to reset the system).