EonStor DS S12/S16/S24 Series Hardware Manual
Inst
alling the DIMM Module
1. Remove the controller module from the chassis. See 5.1 Replacing the
Controlle
r Module for details.
2. (If applicable
) Remove the BBU module. See 5.3.2 Replacing the BBU for
det
ails.
3. Wait for one minute for the remaining electricity on the main board to disperse.
4. Push down the clips on the sides of the DIMM socket. The DIMM will be
ejected from the socket.
DIMM socket
5. Insert the replacement module. Make sure the side clips are in the open
positions. Align the DIMM module with the socket and and firmly push the DIMM
module into the socket. The side clips will close automatically and secure the
DIMM module into the socket.
6. (If applicable) Reinstall the BBU module.
7. Reinstall the controller module into the chassis.
5.3 Replacing the CBM for RAID Models
WARNING
Make sure you have the replacement module(s) in your hand before you attempt to
replace the CBM.
The CBM consists of a battery backup unit (BBU) and flash backup module (FBM).