Integration guide iUC150B & iUC160B
900021059 R11 000 04/0416
Copyright© 2015 Ingenico
All rights reserved
28
4_4 Telium manager
The main functions offered by the manager are the following:
Terminal initialization
Required operating conditions
To operate, the system unit has to be equipped with its system and the application manager.
Terminal Maintenance
Card Recognition and routing to the application
4_5 Software downloading
Local Loading Tool (LLT)
The LLT is used for local software download.
The LLT is formed by:
A PC running with Windows Seven, Vista Pro, XP, 2003 Server, 2000 Professional SP2
A INGENICO loading software,
A PC-terminal connecting cable
Two connections are possible:
By COM link: Speed 115200 bits/s
By slave USB link: Speed 8 Mbits/s approx.
Selection of the software to be loaded is guided on the PC screen by an Explorer type Windows system
(Windows loader).
Loading time for a 1Mo application is 4s by USB port.
Loading and management of memory space in system unit
Before a (down)load, the system ensures that the necessary memory space is available.
The software (possibly compressed) are downloaded to ash.
If software is deleted, the system frees the space. If software is upgraded, the system loads the new
software, checks it, and deletes the old version.
The entire memory area is used and is usable. No area is reserved for upgrades.
On start-up of the terminal (power up or reset), the applications are decompressed and the code is
copied to RAM.
Improved software downloading
Data is compressed in accordance with an algorithm derived from the Lempel-Ziv method ensuring
compression rates of the order of 40 %.
The downloaded software is run in a secure context by authenticity check.