5_Requirements for iUC150B & iUC160B
installation
Note: It is required to use ESD-protective clothing while handling these devices.
5_1 Security requirement
Your device fulls current applicable PCI PTS security requirements.
Upon receipt of your terminal you should check for signs of tampering of the equipment. It is strongly
advised that these checks are performed regularly after receipt. You should check, for example: that
the keypad is rmly in place; that there is no evidence of unusual wires that have been connected to
any ports on your terminal or associated equipment, the chip card reader or any other part of your
terminal. Such checks would provide warning of any unauthorised modications to your terminal, and
other suspicious behaviour of individuals that have access to your terminal. Your terminal detects any
“tampered state”. In this state the terminal will repeatedly ash the message” Alert Irruption!” and
further use of the terminal will not be possible. If you observe the “Alert Irruption!” message, you
should contact the terminal helpdesk immediately.
You are strongly advised to ensure that privileged access to your terminal is only granted to staff that
have been independently veried as being trustworthy.
The terminal must never be put in or left at a location where it could be stolen or replaced by another
device.
You are strongly advises to perform regular checks on the chip card reader.
5_2 Kiosk mechanical requirements
The iUC150B complies with EVA compact module standard. There are 2 ways of installation:
The iUC150B & iUC160B can mounted directly on the kiosk from outside. In that case, the kiosk
panel thickness must be between 2 mm and 14 mm according to EVA standard.
The iUC150B & iUC160B can be mounted on a EVA plate (standard plate or compact plate); in
example for the replacement of a previous contacless reader. In that case, the kiosk panel thickness
must be between 2 mm and 5 mm. With a metallic kiosk panel thickness more than 5mm or with metal
parts near the antenna, the performance might not be correct.
The kiosk panel can be metallic or plastic.
The kiosk panel can be coated with painting but grounding of iUN modules must be insured.
The kiosk panel surface used to mount the product should be planar.
5_3 General installation recommendations
Installation requirements:
Ensure that you have enough free space for installation, operational and maintenance needs.
Magnetic strip card reader and chip card reader required free space above and below the
product to allow correct card reading.
Be aware of the safety regulations.
Product must be mounted vertically and at appropriate height to keep IC card reader slot in
full view for the card holder during all the payment transaction.