SGNe Troubleshooting Guide Page 20
Revision 1.0; Davidson, May 2009. ©Ingersoll Rand Proprietary Information
SGNe
Troubleshooting Guide
Danger
Please utilize extreme caution when performing work within the compressor cabinet.
When opening the cabinet: be certain to wear appropriate PPE (Personal Protective Equipment),
follow lock out-tag out procedures, and ensure all safety procedures are followed
.
Service Menu 91 Test Menu
Fixed Speed Control
Fixed Speed RPM
% Blower Speed
Anti-condensation
Service Menu 218 Field Interface
Configure VSD
Read from VSD
Install Purchased Options
Service Menu 348 Diagnostics
Control Interface Test
Power Module Test
VSD Memory Test
Error Code #1
Error Code #2
Energy Status Messages
While the compressor has power (started or stopped), an energy status screen can be
displayed by the controller. The energy status display can be selected by the operator
by pressing the energy status button. The operator can return the display to the current
status by pressing the status button. The following items and their present values will
be displayed on the right side (area 2) of the screen by pressing the UP and DOWN
arrows.
Average Package kW-hours
This displays the average package kW per hour for the time period that was started by
selecting the reset averaging set point. This value includes the blower power usage.
Average % Capacity
Displays the compressor’s average percent capacity for the time period that was started
by selecting the reset averaging set point. This value is determined by taking the average
package kW per hour, removing the blower power usage, and then dividing that number
by the motor kW per hour for that size of compressor at 100% capacity.
Average Capacity
Displays the compressor’s average capacity in cfm or M3 for the time period that was
started by selecting the reset averaging set point.