Contact-Cooled Rotary Screw Air Compressor
R30, R37, R45, R55, R75, R90, R110, R132, R160
Product Information
Information produit
FR
Información del producto
ES
Product Information
EN
Informações do produto
PT
93014.15.06
PRINT LANGUAGE
ENGLISH
SPANISH
FRENCH
PORTUGUESE

Table of Contents

Other manuals for Ingersoll-Rand R45

Questions and Answers

  • M
    Mark BlackburnSep 23, 2025
    When to change HE filter in integrated dryer models of Ingersoll-Rand Air Compressor?
    • C
      collinsshelbySep 23, 2025
      To address the issue of needing to change the HE filter in integrated dryer models of your Ingersoll-Rand Air Compressor: * If there is a faulty pressure transducer measurement, calibrate and validate the after cooler discharge and package discharge transducers. * If the moisture separator condensate drain trap is faulty, ensure the condensate drain system is functioning properly and condensate is being drained. * If there is a blockage in the dryer, ensure it's not due to freeze up from refrigerant leaks. * If the dryer HE filter is dirty or blocked, change the HE filter.
  • S
    Susan WilliamsAug 26, 2025
    What to do if Ingersoll-Rand R45 Air Compressor is stopped and will not restart?
    • R
      Richard HillAug 26, 2025
      If your Ingersoll-Rand Air Compressor is stopped and won't restart, it could be due to the following reasons: * The controller has tripped the compressor and hasn't been reset. See Tables 4 and 5. * The emergency stop button has been pressed but not released. Identify the reason, repair the fault, disengage the button, and reset the controller. * The emergency stop button has been pressed and released, but the controller hasn't been reset. Repair the fault and reset the controller.
  • J
    Jennifer MasseyAug 27, 2025
    Why does my Ingersoll-Rand Air Compressor stop and not restart?
    • E
      Emma SmithAug 27, 2025
      If your Ingersoll-Rand Air Compressor stops and will not restart, it could be due to: * A tripped drive controller. See Tables 4 and 5. * The controller has tripped the compressor. See Tables 4 and 5. * The maximum number of starts per hour has been exceeded.
  • M
    Mary HernandezAug 28, 2025
    Why is the discharge air from my Ingersoll-Rand R45 too hot?
    • M
      Ms. Alexis RamirezAug 28, 2025
      If the discharge air from your Ingersoll-Rand Air Compressor is too hot, consider these potential causes: * High ambient temperature. Review the installation and system parameters. * Insufficient cooling air. Check the ducting and cooling air path, and verify the direction of blower rotation. * Dirty or blocked aftercooler (cooling air side). Clean or replace the aftercooler.
  • B
    Beth ParkerSep 23, 2025
    What to do if Ingersoll-Rand Air Compressor stops but there is no alarm message?
    • W
      wilsonkeithSep 23, 2025
      If your Ingersoll-Rand Air Compressor stops but there is no alarm message: * There may be a loss of outputs of control power. Check the controller outputs (110V AC) power supply (fuses/mini circuit breaker).
  • J
    John MontoyaNov 24, 2025
    What to do if Ingersoll-Rand Air Compressor will not meet pressure requirements?
    • J
      Jeffrey PerryNov 24, 2025
      If your Ingersoll-Rand Air Compressor isn't meeting the required pressure, consider the following: * Check for air loss due to pipe, hose, joint, or seal failures. Repair or replace any faulty components. * Inspect for air loss due to a blowdown valve stuck open and repair or replace if needed. * Look for air loss through the pressure relief valve if it's not seating correctly or is set incorrectly; repair or replace it. * Check for air loss due to a moisture separator drain trap stuck open; repair or replace it if necessary. * Examine the inlet grill or ducting for blockages and clean them. * Replace the air filter if it's dirty or collapsed. * Recalibrate or replace the pressure transducer if it is faulty, incorrectly calibrated, or experiencing EMF interference. * Verif...
  • D
    Donald RichmondSep 12, 2025
    Why do I need to check setpoints on Ingersoll-Rand Air Compressor?
    • G
      Gavin MeyersSep 12, 2025
      You may need to check the setpoints on your Ingersoll-Rand Air Compressor if: * The controller software has been changed. Recalibrate all sensors and check the setpoints.
  • T
    tmorganSep 12, 2025
    What to do if sensor failure occurs in Ingersoll-Rand Air Compressor?
    • T
      taylorloriSep 13, 2025
      If a sensor failure occurs in your Ingersoll-Rand Air Compressor: * The sensor may be missing or faulty. Install, repair, or replace the faulty sensor.
  • R
    ricky30Sep 5, 2025
    What causes excessive coolant consumption in Ingersoll-Rand Air Compressor?
    • J
      Jeanne KellySep 5, 2025
      Excessive coolant consumption in your Ingersoll-Rand Air Compressor can be due to: * A coolant system leak. Repair or replace the leaking components. * See also ‘discharge air is contaminated with coolant’.
  • T
    Teresa GreenSep 3, 2025
    Why is pressure too high in Ingersoll-Rand Air Compressor because speed is not reducing?
    • S
      Sherri FloresSep 3, 2025
      If the pressure produced by your Ingersoll-Rand Air Compressor is too high because the speed isn't reducing as demand decreases: * The controller settings may be incorrect. Check and modify the settings. * The pressure transducer may be faulty, incorrectly calibrated, or not receiving a pressure signal. Recalibrate or replace it.

Summary

Manual Overview and Safety

About This Manual and Handling

Introduction to the manual, safety, and transportation/handling procedures.

Safety Precautions

Essential safety guidelines for compressor operation and maintenance.

Installation Guidelines

Location, Piping, and Electrical

Procedures for physical placement, piping, and electrical connections.

General Information

Compressor Description and Operation

General description of the compressor's design, operation, and coolant system.

Operating Instructions

VSD Compressor Operations

Step-by-step guide for starting, stopping, and operating VSD compressors.

XE-70 M Controller Operations

Explanation of the controller's interface, navigation, and operation.

System Connectivity and Controls

Modbus Network Setup

Configuration steps for connecting the controller to a Modbus RTU master.

X-Series System Integration

How to integrate the compressor with an X-Series System Controller.

Notices and Warranty

Disclaimers and Warranty Terms

Legal notices, disclaimers, and details on the product warranty.