How to troubleshoot Ingersoll-Rand R45 Air Compressor that will not start?
- MMorgan WilliamsAug 23, 2025
If your Ingersoll-Rand Air Compressor will not start, it could be due to several reasons: * There may be no power supply. Ensure the power is switched on. If it is, contact a qualified electrician. * There may be a controller failure. Check the supply to the controller and replace it if necessary. * There may be a starter failure. Isolate the supply, lock it off, tag it, and replace the failed component. Alternatively, contact your local Ingersoll Rand representative.