Continue Para. Parameter Name Default Commissioning
H03-09 DI4 logic selection 0
1: S-ON (Servo ON)
H03-10 DI5 function selection 1
H03-11 DI5 logic selection 0
……. ………
H03-16 DI8 function selection 31
31: HomeSwitch (Home switch)
H03-17 DI8 logic selection 0
H03-18 DI9 function selection 0
0: No function
H03-19 DI9 logic selection 0
Set AI1 if used as speed
reference
H03-80 Speed corresponding to 10 V 3000
0 to 6000 RPM
H03-54 AI1 zero drift 0
H03-53 AI1 dead zone 10
H03-51 AI1 lter time constant 10
Set AI2 if used as speed
reference
H03-80 Speed corresponding to 10 V 3000
0 to 6000 RPM
H03-59 AI2 zero drift 0
H03-58 AI2 dead zone 10
H03-56 AI2 lter time constant 10
Continue Para. Parameter Name Default Commissioning