Questions and Answers

  • J
    Joshua HaydenAug 15, 2025
    What to do if Inovance MD021S0.2L Inverter displays Err02?
    • Z
      Zachary AustinAug 15, 2025
      If your Inovance Inverter shows Err02, it could be due to several reasons: * The output circuit might be short-circuited: Inspect the output circuit and rectify any faults. * Acceleration time might be too short: Increase the acceleration time. * Torque boost might be too large: Reduce the torque boost. * Voltage might be lower than required: Adjust the voltage to the correct range. * Motor being rotating is started: Start the motor after it completely stops. * Sudden load occurs during acceleration: Eliminate the sudden load.
  • J
    Jennifer RandallAug 18, 2025
    What to do if Inovance MD021S0.2L displays Err04?
    • C
      Cynthia StephensAug 18, 2025
      If your Inovance Inverter displays Err04, it could be due to: * A short-circuited output circuit: Check the output circuit of the inverter and rectify any faults found. * Sudden load during running: Eliminate any sudden load. * Load can be reduced: Reduce the load if possible.
  • C
    Calvin WilsonAug 21, 2025
    What to do if Inovance Inverter displays Err03?
    • G
      Gary CraneAug 21, 2025
      If your Inovance Inverter displays Err03, here are some potential causes and solutions: * Output circuit is short-circuited: Check the output circuit and rectify the fault. * Deceleration time is too short: Increase the deceleration time. * Voltage is lower than the required value: Adjust the voltage to the proper range. * Sudden load occurs during deceleration: Eliminate sudden load.
  • B
    Barbara KeithAug 25, 2025
    Why Inovance MD021S0.2L shows Err05?
    • D
      Diana AdamsAug 25, 2025
      The Err05 error on your Inovance Inverter may be caused by: * Input voltage being too high: Reduce the voltage to the correct range. * Acceleration time being too short: Increase the acceleration time.
  • C
    Christopher NelsonAug 27, 2025
    Why Inovance MD021S0.2L shows Err06?
    • M
      Mary WatsonAug 28, 2025
      The Err06 error on your Inovance Inverter may be triggered by: * Input voltage is too high: Reduce the voltage to the correct range. * Deceleration time is too short: Increase the deceleration time.
  • W
    William FosterAug 30, 2025
    What causes Err09 on Inovance Inverter?
    • L
      Lori MorenoAug 30, 2025
      The Err09 error on your Inovance Inverter can be due to: * Instantaneous power failure: Check for any power failure. * Input voltage being too low: Increase the voltage to the proper range.
  • M
    maciasmackenzieSep 2, 2025
    What causes Err07 on Inovance Inverter?
    • H
      hickmanbiancaSep 3, 2025
      The Err07 error on your Inovance Inverter is caused by input voltage being too high. Reduce the voltage to the proper range.
  • M
    Michelle SteeleSep 5, 2025
    What to do if Inovance MD021S0.2L displays Err16?
    • D
      Danielle FranklinSep 5, 2025
      If your Inovance Inverter shows Err16, it could be due to: * Host computer not working properly: Check the host computer and its connection. * RS485 communication issues: Verify the RS485 communication and check the communication cable. * Incorrect communication parameters: Ensure the communication parameters in group F3 are correctly set; if not, modify them.
  • S
    Samantha StewartSep 8, 2025
    What to do if Inovance MD021S0.2L displays Err14?
    • J
      Jennifer TerrySep 8, 2025
      If your Inovance Inverter displays Err14, it might be because: * The ambient temperature is too high: Reduce the ambient temperature. * The air ventilation channel is blocked: Clear the air ventilation channel.
  • B
    Benjamin MartinezSep 12, 2025
    How to fix Err13 on Inovance MD021S0.2L Inverter?
    • G
      gregorygutierrezSep 12, 2025
      Replace the operation panel or drive board and then check whether the fault is rectified.

Summary

Safety and Precautions

Installation Safety Precautions

Guidelines and warnings for installing the inverter safely.

Running Safety Precautions

Safety measures to follow during the operation of the inverter.

Mechanical and Electric Installation

Installation Environment Requirements

Requirements for the environmental conditions during installation.

Operation Panel and Wiring Guide

Instructions for connecting the operation panel and wiring the inverter.

Operation Panel Indicators

Explanation of the indicators found on the inverter's operation panel.

Wiring Terminal Descriptions

Detailed description of each terminal on the inverter's backside.

Operation and Display

Function Code Table

Description of Function Codes

Troubleshooting

Fault Code Solutions

Detailed list of error codes, their causes, and troubleshooting steps.

Inovance MD021S0.2L Specifications