MD280/MD280N User Manual Preface
I
Preface
Thank you for purchasing MD280 Series inverter.
This instruction manual describes how to use MD280 series inverter
properly. Please completely understanding this user’s manual before
installing, operating, and maintenance or inspecting.
Safety Precautions
The drawings presented in this instructions are sometimes shown
without covers or protective guards.Always replace the equipment’s
cover or protective guard as specified first,and the operate the
products in accordance with the instructions.
z The drawings presented in the instructions are typical examples
and may not match the product you received.
z These instructions are subject to change due to product
improvement, specification modification, specification modification.
z If you want to order the manual due to loss or damage, please
contact our company agents in each region or our company customer
service center directly.
z If there is still any problem during using the product, please
contact our company customer service center directly.
z Our Service Hotline: 400-777-1260.
efesotomasyon.com

Table of Contents

Questions and Answers

  • T
    tannertimothySep 18, 2025
    Why does Inovance Inverter display "H&" and stops immediately?
    • D
      Dr. Joseph DownsSep 19, 2025
      If the AC drive display is normal upon power-on but "H&" is displayed after running and the AC drive stops immediately, the cooling fan is damaged or locked-rotor occurs. Replace the damaged fan.
  • V
    Vanessa LongAug 25, 2025
    What to do if Inovance Inverter shows overcurrent during deceleration?
    • J
      Jose GrahamAug 25, 2025
      If your Inovance Inverter indicates overcurrent during deceleration, it could be due to a grounded or short-circuited output circuit, a deceleration time that is too short, low voltage, a sudden load added during deceleration, or the absence of a braking unit and braking resistor. Consider the following solutions: * Replace external faults. * Increase the deceleration time. * Adjust the voltage to the normal range. * Remove the added load. * Install the braking unit and braking resistor.
  • J
    Jason MitchellAug 25, 2025
    Why does Inovance MD280NT37P Inverter show overcurrent at constant speed?
    • J
      Jeremy WarnerAug 26, 2025
      An Inovance Inverter displaying overcurrent at a constant speed may be caused by a grounded or short-circuited output circuit, a sudden load added during operation, or the AC drive model being of too small a power class. To address this: * Replace external faults. * Remove the added load. * Select an AC drive of a higher power class.
  • J
    John BoydAug 27, 2025
    How to resolve overvoltage during deceleration in Inovance MD280NT37P?
    • B
      Brenda Nichols PhDAug 27, 2025
      If you are experiencing overvoltage during deceleration with your Inovance Inverter, the possible causes are: the input voltage is too high, an external force drives the motor during deceleration, the deceleration time is too short, or the braking unit and braking resistor are not installed. Here are some possible solutions: * Adjust the voltage to the normal range. * Cancel the external force or install the braking resistor. * Increase the deceleration time. * Install the braking unit and braking resistor.
  • U
    umckinneySep 23, 2025
    What does "Err23" displayed at power-on mean for Inovance MD280NT37P?
    • J
      Jason ChavezSep 23, 2025
      If "Err23" is displayed at power-on, the motor or the motor output cable is short-circuited to the ground. Measure the insulation of the motor and the output cable with a megger.
  • J
    Jacqueline NovakSep 23, 2025
    Why is there no display at power-on on Inovance Inverter?
    • E
      Emily BarnesSep 23, 2025
      If there is no display at power-on, there is no power supply to the AC drive or the power input to the AC drive is too low. Check the power supply. Also, the cable connecting the control board and the drive board and the operation panel breaks. Re-connect the 8-core and 16-core cables.
  • L
    Laura HollandSep 10, 2025
    How to resolve initial position fault on Inovance Inverter?
    • R
      riverachristopherSep 10, 2025
      An initial position fault may occur because the motor parameters are not set based on the actual situation. Check whether the motor parameters are set correctly and whether the setting of rated current is too small.
  • C
    Connor LopezSep 12, 2025
    What causes motor overheat with Inovance MD280NT37P?
    • C
      Christopher HuffSep 12, 2025
      Motor overheat when using an Inovance Inverter can be caused by the cabling of the temperature sensor becoming loose or the motor temperature being too high. Check the temperature sensor cabling and eliminate the cabling fault. You can also lower the carrier frequency or adopt other heat radiation measures.
  • P
    patrickperezSep 3, 2025
    What causes power input phase loss in Inovance MD280NT37P?
    • B
      Benjamin PerrySep 3, 2025
      Power input phase loss in your Inovance Inverter may be due to the three-phase power input being abnormal. You can try to replace external faults.
  • A
    Ashley RodriguezSep 1, 2025
    What to do if Inovance MD280NT37P Inverter displays motor overload?
    • S
      Shelby WebbSep 1, 2025
      If your Inovance Inverter indicates a motor overload, possible causes include FB-01 being set improperly, the load being too heavy or locked-rotor occurring on the motor, or the AC drive model being of too small a power class. To resolve this: * Set FB-01 correctly. * Reduce the load and check the motor and mechanical conditions. * Select an AC drive of larger power class.

Summary

Preface

Safety Precautions

General warnings and guidelines for safe operation and handling of the inverter.

Chapter 1 Safety and Precautions

1.1 Safety precautions

Essential safety measures to be followed before, during, and after installation and operation.

1.2 Precautions

Important considerations and warnings related to motor, electrical, and environmental factors.

Chapter 2 Product Information

2.4 Technical Specifications

Detailed technical data and performance characteristics of the inverter.

2.7 Routine Repair and Maintenance of Inverter

Procedures for regular inspection, cleaning, and maintenance to ensure optimal performance.

Chapter 3 Mechanical and Electrical Installation

Chapter 4 Operation and Display

Chapter 5 Function Parameter Table

Chapter 6 Parameter Description

Chapter 7 EMC (Electromagnetic Compatibility)

Chapter 8 Fault Diagnosis and Countermeasures

8.1 Fault Alarm and Countermeasures

Explanation of warning codes and initial troubleshooting steps for inverter faults.

8.2 Common Fault and Resolution

Table of common faults, their causes, and recommended solutions for troubleshooting.

Inovance MD280NT37P Specifications

General IconGeneral
ModelMD280NT37P
Rated Output Power37 kW
Output Current75 A
Protection LevelIP20
Cooling MethodForced Air Cooling
TypeInverter