Preface
Thanks for using the MD300A series inverter presented by Inovance Technology Co., Ltd..
Developed on the basis of extensive market research, MD300A series inverter is a general-purpose
inverter with high performance.
Embodying the features of products offered by Inovance Technology Co., Ltd., the inverter bears
two control modes, that is, V/F and open-loop vector, and ensures the best low frequency torque
and dynamic response performance.
Many new functions have been added on the basis of the market research and analysis of the
customer’s function requirements. This series of products are the true high-performance inverters
with general-purpose function.
The manual presents the precaution details related to the installation, parameter adjustment,
abnormal problems diagnosis and daily maintenance of the inverter. Please carefully read the
manual before the installation and keep it safe for future maintenance reference.
Special precautions as follows:
Do remember to cut off the power supply upon wiring. After cutting off the AC power, do not
touch the internal parts and components until at least 5 minutes later, since it takes some time
for the electric charge stored in the capacitor of the inverter to discharge.
Do not touch the PCB or drop foreign material into the inverter, otherwise it may cause short
circuit, because many components inside the inverter are static sensitive devices.
The grounding terminal of the inverter shall be reliably connected to the earth with multicore
cable.
Do not connect AC input power to the output terminals U, V and W of the inverter.
The external braking resistor can only be connected between terminal P and terminal PB.
Question and Answer IconNeed help?

Do you have a question about the Inovance MD300A-S0.2BA and is the answer not in the manual?

Inovance MD300A-S0.2BA Specifications

General IconGeneral
Power0.2 kW
Control MethodV/F control, Sensorless vector control
Storage Temperature-20°C to +60°C
Input VoltageSingle-phase 220V AC
Output Voltage3-phase 220V AC
Frequency Range0 Hz - 400 Hz
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Short circuit
Cooling MethodAir cooling
Communication InterfaceRS-485
Operating Temperature-10°C to +50°C
Humidity5% to 95% RH (non-condensing)
Altitude0 to 1000m, derating above 1000m

Summary

Chapter 7 Fault Diagnosis and Countermeasures

Fault Alarm and Countermeasures

Lists inverter alarm information and provides troubleshooting steps for various fault codes.

Common Faults and the Fault Diagnosis

Common issues encountered during operation and methods for diagnosing and resolving them.

Chapter 1 Delivery Inspection and Safety Cautions

Installation Cautions

Key safety guidelines for environmental conditions and physical mounting of the inverter to ensure proper operation.

Running and Maintenance Cautions

Important safety advice for operating and maintaining the inverter, highlighting potential hazards.

Chapter 2 Product Information

Chapter 3 Mechanical and Electrical Installation

Basic Electrical Installation

Details the wiring of power input, DC bus, braking resistor, and output terminals for correct setup.

Chapter 4 Operation and Display

Chapter 5 Function Parameters

Related product manuals