MD021 Plastic Wire Drawing Machine User Manual
This parameter is valid only when "Frequency source selection"
(F0-01) is set to "Digital setting". When "Frequency source selection"
(F0-01) is set to "Digital setting", this parameter is the initial preset
value of the inverter.
"Acceleration time" specifies the time T1 required for the inverter to
increase from 0 Hz to the maximum output frequency (F0-02).
"Deceleration time" specifies the time T2 required for the inverter to
decrease from the maximum output frequency (F0-02) to 0 Hz.
Figure 6-1 shows the acceleration time and deceleration time.
Figure 6-1 Acceleration time and deceleration time