MD021 Plastic Wire Drawing Machine User Manual
Output
frequency Hz
Maximum
frequency
Preset
frequency
Actual acceleration time
Set acceleration time
Actual deceleration time
Set deceleration time
Time t
t1 t2
Note: If "Deceleration time" (F0-05) is set to 0, the stop mode of the
inverter is free stop.
Function
Code
Name
Range
Default
F0-06
Motor rated
power
0.1 kW
to1000.0 kW
Depend on the
motor power
F0-07
Motor rated
voltage
0 V to 480 V
Depend on the
motor power
F0-08
Motor rated
current
0.1 A to
6553.5 A
Depend on the
motor power
F0-09
Motor rated
frequency
0.01 Hz to
maximum
frequency
(F0-02)
Depend on the
motor model