MD021 Plastic Wire Drawing Machine User Manual
controlled value at the target value.
It is applicable to such process controls as flow control, pressure
control and temperature control. Figure 6-4 shows the block diagram
of the basic control principle.
Figure 6-4 Block diagram of the basic control principle
Target
Feedback
Deviation
limit
Function
Code
Name
Range
Default
F2-00
PID setting
source
0: F2-01
1: Via
communication
0
This parameter specifies the channel of setting the target value of
process PID.
The target value of process PID is a relative value ranges from 0.0%
to 100.0%, which corresponds to the percentage of the feedback signal
from the controlled system.