Function Code Table
MD280 User Manual
- 82 -
Function
Code
Parameter Name Setting Range
Min.
Unit
Default
Property
F2-17
Corresponding
setting mode of AI2
PD[LPXPLQSXW
0: F2-18
1: Determined by AI1
10
ƾ
F2-18
Corresponding
setting of AI2
PD[LPXPLQSXW
-100.00%–100.0% 0.1% 100.0%
ƿ
F2-19 $,¿OWHUWLPH 0.00–10.00s 0.01s 0.10s
ƿ
F2-20
Pulse minimum
input
0.00 kHz to F2-22
0.01
kHz
0.00 kHz
ƿ
F2-21
Corresponding
setting of pulse
minimum input
-100.00%–100.0% 0.1% 0.0%
ƿ
F2-22
3XOVHPD[LPXP
input
F2-20 to 50.00 kHz
0.01
kHz
50.00 kHz
ƿ
F2-23
Corresponding
setting mode of
SXOVHPD[LPXP
input
0: F2-24
1: Determined by AI1
2: Determined by AI2
10
ƾ
F2-24
Corresponding
setting of pulse
PD[LPXPLQSXW
-100.00%–100.0% 0.1% 100.0%
ƿ
F2-25 3XOVH¿OWHUWLPH 0.00–10.00s 0.01s 0.10s
ƿ
F2-26
DI valid state
selection
0–127 1 0
ƿ
F2-27
Function selection
of AI1 used as DI6
Same as F2-00 1 0
ƾ
F2-28
Function selection
of AI1 used as DI7
Same as F2-00 1 0
ƾ
Group F3: Output Terminals
F3-00
FM terminal output
mode
3XOVHRXWSXW)03
'2RXWSXWRXWSXW)05
2: AO output
12
ƿ
F3-01
Relay function
selection
0: No output
1: AC drive running
2: Fault output 1
3: Frequency-level detection
FDT output
4: Frequency reached
5: Upper limit frequency
reached
6: Lower limit frequency
reached
7REHFRQWLQXHG
12
ƿ