Function Code Table
MD280 User Manual
- 84 -
Function
Code
Parameter Name Setting Range
Min.
Unit
Default
Property
F3-10
DO1 output delay
time
0.0–3600.0s 0.1s 0.0s
ƿ
F3-11
DO2 output delay
time
0.0–3600.0s 0.1s 0.0s
ƿ
F3-12
DO3 output delay
time
0.0–3600.0s 0.1s 0.0s
ƿ
F3-13
DO valid state
selection
0–15 1 0
ƿ
F3-14
Motor switchover
delay
0.1–32.0s 0.1s 0.1s
ƿ
F3-15
Startup delay after
motor switchover
0.1–32.0s 0.1s 0.2s
ƿ
Group F4: Start/Stop Control
F4-00 Start mode
0: Direct start
1: Rotational speed tracking
restart
10
ƾ
F4-01
Rotational speed
tracking mode
0: From frequency at stop
1: From zero speed
)URPPD[LPXPIUHTXHQF\
10
ƿ
F4-02
Rotational speed
tracking speed
1–100 1 20
ƿ
F4-03 Startup frequency
0.00 HzWRPD[LPXP
IUHTXHQF\)
0.01 Hz 0.00 Hz
ƾ
F4-04
Startup frequency
holding time
0.0–36.0s 0.1s 0.0s
ƾ
F4-05
Startup DC braking
current
0%–100% 1% 0%
ƾ
F4-06
Startup DC braking
time
0.0–36.0s 0.1s 0.0s
ƾ
F4-07
Acceleration/
Deceleration mode
0: Linear acceleration/
deceleration
1: S-curve acceleration/
deceleration A
2: S-curve acceleration/
deceleration B
10
ƾ
F4-08
Time proportion
of S-curve start
segment
0.0% to 100.0% 0.1% 20.0%
ƾ
F4-09
Time proportion
of S-curve end
segment
0.0% to 100.0% 0.1% 20.0%
ƾ