EasyManua.ls Logo

Inovance MD290T160G/200P - Main Circuit Wiring

Inovance MD290T160G/200P
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Electrical Installation
- 49 -
3
3.2 Main Circuit Wiring
3.2.1 Main Circuit Terminals
Ƶ
Terminal Arrangement
MD29018.5G/22P to MD29037G/45P
MD290T45G/55P to MD290132G/160P
R S
POWER
T
BR
(+)
(-)
V
U
W
MOTOR
MD290T200G
to
MD290T450G and MD290T220P
to
MD290T500P
U
V
W
Ƶ
Terminal Function
Table 3-1 Description of input and output connections of the drive
Terminal Name Description
R, S, T Three-phase supply input Connected to three-phase power supply.
(+), (-) DC bus terminals Connected to external braking unit (MDBUN) with
AC drive units of 90 kW and above.
(+), BR Braking resistor
connection
Connected to external braking resistor for AC drive
units of 75 kW and below.
U, V, W AC drive outputs Connected to a three-phase motor.
Ground (PE) Grounding connection.

Table of Contents

Related product manuals