EasyManua.ls Logo

Inovance MD380 Series - Page 112

Inovance MD380 Series
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Code Table
MD380 User Manual
- 112 -
Function
Code
Parameter Name
Setting Range
Default Property
F9-47
Fault protection
action selection 1
8QLWVGLJLW0RWRURYHUORDG(UU
00000 ƿ
0: Coast to stop
1: Stop according to the stop
mode
2: Continue to run
Ten's digit (Power input phase
loss, Err12)
Same as unit's digit
Hundred's digit (Power output
phase loss, Err13)
Same as unit's digit
Thousand's digit (External
equipment fault, Err15)
Same as unit's digit
Ten thousand's digit
(Communication fault, Err16)
Same as unit's digit
F9-48
Fault protection
action selection 2
8QLWVGLJLW(QFRGHU3*FDUG
fault, Err20)
00000 ƿ
0: Coast to stop
1: Switch over to V/F control, stop
according to the stop mode
2: Switch over to V/F control,
continue to run
7HQVGLJLW((3520UHDGZULWH
fault, Err21)
0: Coast to stop
1: Stop according to the stop
mode
F9-48
Fault protection action
selection 2
Hundred's digit: reserved
00000 ƿ
Thousand's digit (Motor overheat,
Err25)
Same as unit's digit in F9-47
Ten thousand's digit
(Accumulative running time
reached)
Same as unit's digit in F9-47
efesotomasyon.com

Table of Contents

Related product manuals