MD380 User Manual Function Code Table
- 125 -
Function
Code
Parameter Name
Setting Range
Default Property
*URXS$9LUWXDO',9',9LUWXDO'29'2
A1-00 VDI1 function selection
0–59
0 ƾ
A1-01 VDI2 function selection
0–59
0 ƾ
A1-02 VDI3 function selection
0–59
0 ƾ
A1-03 VDI4 function selection
0–59
0 ƾ
A1-04 VDI5 function selection
0–59
0 ƾ
A1-05 VDI state setting mode
'HFLGHGE\VWDWHRI9'2[
1: Decided by A1-06
00000 ƾ
8QLWVGLJLW9',
Ten's digit: VDI2
Hundred's digit (VDI3)
Thousand's digit (VDI4)
Ten thousand's digit (VDI5)
A1-06 VDI state selection
0: Invalid
1: Valid
00000 ƾ
8QLWVGLJLW9',
Ten's digit: VDI2
Hundred's digit (VDI3)
Thousand's digit (VDI4)
Ten thousand's digit (VDI5)
A1-07
Function selection for AI1
used as DI
0–59
0 ƾ
A1-08
Function selection for AI2
used as DI
0–59
0 ƾ
A1-09
Function selection for AI3
used as DI
0–59
0 ƾ
A1-10
State selection for AI used
as DI
0: High level active
1: Low level active
000 ƾ
8QLWVGLJLW$,
Ten's digit: AI2
Hundred's digit: AI3