EasyManua.ls Logo

Inovance MD380 Series - Page 125

Inovance MD380 Series
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD380 User Manual Function Code Table
- 125 -
Function
Code
Parameter Name
Setting Range
Default Property
*URXS$9LUWXDO',9',9LUWXDO'29'2
A1-00 VDI1 function selection
0–59
0 ƾ
A1-01 VDI2 function selection
0–59
0 ƾ
A1-02 VDI3 function selection
0–59
0 ƾ
A1-03 VDI4 function selection
0–59
0 ƾ
A1-04 VDI5 function selection
0–59
0 ƾ
A1-05 VDI state setting mode
'HFLGHGE\VWDWHRI9'2[
1: Decided by A1-06
00000 ƾ
8QLWVGLJLW9',
Ten's digit: VDI2
Hundred's digit (VDI3)
Thousand's digit (VDI4)
Ten thousand's digit (VDI5)
A1-06 VDI state selection
0: Invalid
1: Valid
00000 ƾ
8QLWVGLJLW9',
Ten's digit: VDI2
Hundred's digit (VDI3)
Thousand's digit (VDI4)
Ten thousand's digit (VDI5)
A1-07
Function selection for AI1
used as DI
0–59
0 ƾ
A1-08
Function selection for AI2
used as DI
0–59
0 ƾ
A1-09
Function selection for AI3
used as DI
0–59
0 ƾ
A1-10
State selection for AI used
as DI
0: High level active
1: Low level active
000 ƾ
8QLWVGLJLW$,
Ten's digit: AI2
Hundred's digit: AI3