1: Two-wire control mode 2
,QWKLVPRGH',LV581HQDEOHGWHUPLQDODQG',GHWHUPLQHVWKHUXQQLQJGLUHFWLRQ
The parameters are set as below:
Function Code Parameter Name Value Function Description
F4-11 Terminal command mode 1 Two-wire control mode 2
F4-00 DI1 function selection 1 581HQDEOHG
F4-01 DI2 function selection 2 Forward or reverse direction
Figure 6-8 Setting of two-wire control mode 2
DI1
DI2
&20
MD380
581HQDEOHG
581
K1 K2
00
01
1
0
11
Stop
Stop
Forward
Reverse
K1
K2
Digital common
Forward or reverse direction
$VVKRZQLQWKHSUHFHGLQJ¿JXUHLI.LV21WKH$&GULYHLQVWUXFWVIRUZDUGURWDWLRQ
ZKHQ.LV2))DQGLQVWUXFWVUHYHUVHURWDWLRQZKHQ.LV21,I.LV2))WKH$&
drive stops.
2: Three-wire control mode 1
,QWKLVPRGH',LV581HQDEOHGWHUPLQDODQGWKHGLUHFWLRQLVGHFLGHGE\',DQG',
The parameters are set as below:
Function Code Parameter Name Value Function Description
F4-11 Terminal command mode 2 Three-wire control mode 1
F4-00 DI1 function selection 1 )RUZDUG581):'
F4-01 DI2 function selection 2 5HYHUVH5815(9
F4-02 DI3 function selection 3 Three-wire control
Figure 6-9 Setting of three-wire control mode 1
MD380
DI1
&20
Digital common
DI2
)RUZDUG581():')
5HYHUVH581(REV)
DI3
581HQDEOHG
SB1
SB2
SB3
Forward
button
Reverse
button
Stop
button
efesotomasyon.com