Description of Function Codes
MD380 User Manual
- 184 -
*URXS)2SHUDWLRQ3DQHODQG'LVSOD\
Function Code Parameter Name Setting Range Default
F7-01
MF.K Key function
selection
0: MF.K key disabled
1: Switchover between operation panel
control and remote control (terminal or
communication)
2: Switchover between forward rotation
and reverse rotation
3: Forward jog
4: Reverse jog
0
MF.K key refers to multifunctional key. You can set the function of the MF.K key by using this
parameter. You can perform switchover by using this key both in stop or running state.
 0: MF.K key disabled
This key is disabled.
 1: Switchover between operation panel control and remote control (terminal or
communication)
You can perform switchover from the current command source to the operation panel
control (local operation). If the current command source is operation panel control, this
key is invalid.
 2: Switchover between forward rotation and reverse rotation
You can change the direction of the frequency reference by using the MF.K key. It is
valid only when the current command source is operation panel control.
 3: Forward jog
<RXFDQSHUIRUPIRUZDUGMRJ)-2*E\XVLQJWKH0).NH\
 4: Reverse jog
<RXFDQSHUIRUPUHYHUVHMRJ)-2*E\XVLQJWKH0).NH\
Function Code Parameter Name Setting Range Default
F7-02
67235(6(7NH\
function
0: Stop function enabled only in
operation panel control
1: Stop function enabled in any
operation mode
1