Product Information MD380 User Manual
- 20 -
The housing types of the MD380 models with different voltage and power classes are listed
in the following table.
Table 2-1 Housing types for different voltage and power classes
Voltage & Power Class Housing Type
Single-phase 220 V
±N: Plastic housing
Three-phase 220 V
±N: Plastic housing
±N: Sheet metal housing
Three-phase 380 V
±N: Plastic housing
±N: Sheet metal housing
Three-phase 480 V
±N: Plastic housing
±N: Sheet metal housing
Three-phase 690 V
±N: Sheet metal housing
7HFKQLFDO6SHFL¿FDWLRQV
7DEOH7HFKQLFDOVSHFL¿FDWLRQVRIWKH0'
Item
6SHFL¿FDWLRQV
Standard
functions
Maximum
frequency
Vector control: 0–500 Hz
V/F control: 0–500 Hz
Carrier frequency
0.5–16 kHz
The carrier frequency is automatically adjusted based on
the load features.
Input frequency
resolution
Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
Control mode
Sensorless vector control (SVC)
Closed-loop vector control (CLVC)
V/F control
Startup torque
G type: 0.5 Hz/150% (SVC); 0 Hz/180% (CLVC)
P type: 0.5 Hz/100%
Speed range
1:100 (SVC)
1:1000 (CLVC)
Speed stability
accuracy
f0.5% (SVC)
f0.02% (CLVC)
Torque control
accuracy
±5% (CLVC)
efesotomasyon.com