Product Information MD380 User Manual
- 24 -
3HULSKHUDO(OHFWULFDO'HYLFHVDQG6\VWHP&RQ¿JXUDWLRQ
:KHQWKH0'LVXVHGWRFRQWUROWKHDV\QFKURQRXVPRWRUWRIRUPDFRQWUROV\VWHPLWLV
necessary to install various electrical devices on the input and output sides of the AC drive
to ensure system safety and stability.
In addition, several optional extension cards are available for the MD380 to implement
various functions. The system configuration of three-phase 220/380/480 V AC drive is
VKRZQLQWKHIROORZLQJ¿JXUH
)LJXUH6\VWHPFRQ¿JXUDWLRQRIWKUHHSKDVH9$&GULYH
Output reactor
R
S
T
P(+)
:
V
8
MF.K
RUN
STOP
RES
QUICK
PRG ENTER
RUN
LOCAL/REMOT FED/REV TUNE/TC
RPM
%
AVHz
BR
+
-
MD380
Three-phase AC
power supply
Moulded case circuit
breaker (MCCB) or earth
leakage circuit breaker
(ELCB)
Electromagnetic
contactor
Noise filter on
input side
AC input
reactor
8VHZLWKLQWKHDOORZDEOHSRZHU
supply specification of the AC drive.
Select a proper breaker to resist
large in-rush current that flows
into the AC drive at power-on.
To guarantee safety, use an
electromagnetic contactor. Do not
use it to start or stop the AC drive
because such operation reduces
the service life of the AC drive.
Suppress the high order harmonic
to improve the power factor.
Reduce the electromagnetic
interference on the input side.
Ground
Reliably ground the motor
and the AC drive to
prevent electric shock
Braking unit
Braking resistor
Ground
Motor
efesotomasyon.com