Operation, Display and Application Examples
MD380 User Manual
- 56 -
,QUXQQLQJVWDWH¿YHUXQQLQJVWDWXVSDUDPHWHUVDUHGLVSOD\HGE\GHIDXOWUXQQLQJIUHTXHQF\
frequency reference, bus voltage, output voltage and output current. You can set whether
other parameters are displayed by setting F7-03 and F7-04, as listed in the following table.
Function
Code
Parameter
Name
Setting Range Default
F7-03
LED display
running
parameters 1
7 6 5 4 3 2 1 0
Running frequency 1 (Hz)
Frequency reference (Hz)
Bus voltage
2XWSXWYROWDJH
2XWSXWFXUUHQW(A)
2XWSXWSRZHU(N:)
2XWSXWWRUTXH(%)
DI state
15 14 12 11 10 9 8
'2VWDWH
AI1 voltage (V)
Count value
Length value
Load speed display
PID reference
13
AI2 voltage (V)
AI3 voltage (V)
1F
F7-04
LED display
running
parameters 2
7 6 5 4 3 2 1 0
PID feedback
PLC stage
Pulse reference
Running frequency 2 (Hz)
Remaining running time
AI1 voltage before correction
AI2 voltage before correction
AI3 voltage before correction
15 14 12 11 10 9 8
Linear speed
Current power-on time
Current running time
Pulse reference
Communication reference
Encoder feedback speed
Main frequency X display (Hz)
Auxiliary frequency Y display (Hz)
13
0