MD380 User Manual                                                                                               Function Code Table
- 97 -
Function 
Code
Parameter Name
Setting Range
Default Property
F4-33 AI curve selection
8QLWVGLJLW$,FXUYHVHOHFWLRQ
321 ƿ
Curve 1 (2 points, see F4-13 to 
F4-16)
Curve 2 (2 points, see F4-18 to 
F4-21)
Curve 3 (2 points, see F4-23 to 
F4-26)
Curve 4 (4 points, see A6-00 to 
A6-07)
Curve 5 (4 points, see A6-08 to 
A6-15)
Ten's digit (AI2 curve selection)
Same as AI1
Hundred's digit (AI3 curve 
selection)
Same as AI1
F4-34
Setting for AI less than 
minimum input 
8QLWVGLJLW6HWWLQJIRU$,OHVV
than minimum input)
000 ƿ
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less 
than minimum input)
Same as AI1
Hundred's digit (Setting for AI3 
less than minimum input)
Same as AI1
F4-35 DI1 delay
0.0–3600.0s
0.0s ƾ
F4-36 DI2 delay
0.0–3600.0s
0.0s ƾ
F4-37 DI3 delay
0.0–3600.0s
0.0s ƾ
 
efesotomasyon.com