Technical Data
‑120‑
7 Technical Data
7.1 Electrical Specifications
Note
The rated power of AC drives in the following tables is measured under the following
conditions:
● For three‑phase 380 V to 480 V models, the input voltage is 440 VAC.
● For three‑phase 200 V to 240 V models, the input voltage is 220 VAC.
● For single‑phase 200 V to 240 V models, the input voltage is 220 VAC.
Three phase 380-480 V
Table 7–1 Electrical specifications of T1 models (three phase 380‑480 V)
Item
Specification
Model: MD520‑4Txxxxx
0.4B(S) 0.7B(S) 1.1B(S) 1.5B(S) 2.2B(S) 3.0B(S)
Structure T1
Output
Power (kW) (heavy load)
0.4 0.75 1.1 1.5 2.2 3
Power (kW) (light load)
0.75 1.1 1.5 2.2 3 3.7
Rated output current (A)
(heavy load)
1.5 2.1 3.1 3.8 5.1 7.2
Rated output current (A)
(light load)
2.1 3.1 3.8 5.1 7.2 9
Output voltage Three phase, 0 V to input voltage
Max. output frequency 599 Hz (editable through parameter)
Carrier frequency 0.5 kHz to 16.0 kHz (automatically adjusted according to the load)
Overload capacity
60s at 150% the rated current
Input
Rated input current (A)
(heavy load)
1.8 2.4 3.7 4.6 6.3 9
Rated input current (A) (light
load)
2.5 3.7 4.6 6.4 9.1 11.3
Rated voltage/frequency Three phase 380‑480 VAC, 50/60 Hz
Allowable voltage fluctuation
range
‑15% to +10%, or 323‑528 VAC
Allowable frequency
fluctuation range
±5% or 47.5‑63 Hz
Power supply capacity (kVA)
(heavy load)
2 2.8 4.1 5 6.7 9.5
Power supply capacity (kVA)
(light load)
2.8 4.1 5 6.7 9.5 12