Technical Data
‑133‑
Item
Specification
Contin
ued
Acceleration/
deceleration
curve
Straight‑line or S‑curve acceleration/deceleration
Four groups of acceleration/deceleration time ranging from
0.0s to 6500.0s are supported.
DC braking Starting frequency of DC braking: 0.00 Hz to the maximum
frequency
Braking time: 0.0s to 36.0s
Braking current level: 0.0% to 100.0%
Jog control Frequency range of jog running: 0.00 Hz to 50.00 Hz
Acceleration/deceleration time of jog running: 0.0s to
6500.0s
Simple PLC,
multi‑speed
running
The product supports up to 16 speeds with the built‑in PLC
or control terminal.
Built‑in
proportiona
l–integral–deri
vative (PID)
The function facilitates closed‑loop control of process
control.
Auto voltage
regulation
(AVR)
When the mains voltage changes, the output voltage keeps
constant automatically.
Overvoltage/
overcurrent
stall control
The function limits the current and voltage automatically
during operation to prevent frequent trips caused by
overvoltage or overcurrent.
Fast current
limit
The function helps minimize overcurrent faults.
Torque limit
and control
The function limits the torque automatically during
operation to prevent frequent trips caused by overcurrent.
Torque control can be implemented in vector control mode.
Custom
ized
functions
Power dip ride‑
through
Load regenerative energy compensates for voltage reduction
during instantaneous power failure, allowing the AC drive to
continue operating for a short time.
Virtual I/O
Five groups of virtual digital inputs/outputs (DIs/DOs)
support simple logic control.
Timing control
Time range: 0.0–6500.0 minutes
Multi‑thread
bus
Six buses are supported, including Modbus (Modbus‑RTU,
Modbus‑ASCII, Modbus‑TCP/IP), PROFIBUS DP, CANlink,
CANopen, PROFINET, EtherCAT, and Ethernet/IP.
Encoder type Encoders of the following types are supported: differential,
collector, push‑pull, resolver, and 23‑bit.
Advanced
software tool
The tool supports operations of AC drive parameters and
virtual oscillograph function, through which the state inside
the AC drive is monitored.
Motor overheat
protection
AI2 can input signals of the motor temperature sensor
(PT100, PT1000, KTY‑84‑130, and PTC‑130).