Technical Data
134
Item
Specification
Running Running
command
Running commands can be given through the operating
panel, control terminal, or serial port communication, which
can be switched over in various ways.
Frequency
reference
The drive supports 10 frequency references, which can be
set through digital settings, analog voltage, analog current,
pulse, or serial port communication. These setting sources
can be switched over in various ways.
Auxiliary
frequency
reference
The drive supports 10 auxiliary frequency references. It can
implement fine tuning of the auxiliary frequency and
frequency synthesis.
Input terminal Standard:
Five DIs
Two AIs, AI1 and AI2. AI1 supports only ‑10 V to +10 V voltage
input, and AI2 supports ‑10 V to +10 V voltage input, 0 mA to
20 mA current input, and temperature input, which can be
switched over through the DIP switch.
Extension capability:
Five DIs
Output
terminal
Standard:
One DO
One relay output terminal
One FM (can be set with high‑speed pulse output or
common DO function)
One AO, supporting 0 mA to 20 mA current output or 0 V to
10 V voltage output
Extension capability:
One DO
One relay output terminal
Display
and
operation
on the
operating
panel
LED display It displays parameters.
LCD display
Optional and two languages (Chinese or English) available
Parameter
copy
Quick parameter copy through the optional LCD operating
panel
Key locking
and function
selection
The function can be used to lock the keys partially or
completely and limit the availability of some keys to prevent
accidental operation.