- 107 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-45 is used to select the attendant-related elevator functions. Each bit of the parameter denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
When F6-45 Bit2 = 1, the elevator stops at the emergency evacuation parking oor set in F6-49.
When F6-45 Bit2 = 0, the elevator stops at the nearest landing oor.
The functions dened by the binary bits of F6-45 are described in the following table.
Bit Function Description Default
Bit0
Direction determine mode
0
Automatically
calculating
direction
0
Load direction
determining (based
on load cell data or
half-load signal)
1
Direction of
nearest landing
oor
0
Bit1 0 1 0
0
Bit2
Stopping at evacuation
parking oor
During evacuation running, the elevator arrives at the evacuation
parking oor set in F6-49 (it must be a non-zero value and is a
service oor). Otherwise, the elevator stops at the nearest oor.
0
Bit3 Reserved - 0
Bit4 Compensation at startup
The non-load-cell startup is still valid in the process of evacuation
running.
0
Bit5 Reserved - 0
Bit6 Reserved - 0
Bit7 Reserved - 0
Bit8
Emergency running time
protection
If the elevator does not arrive at the required oor after 50s
emergency evacuation running time, E33 is reported. In this case,
the function of switching over shorting stator braking mode to
controller drive based on the time setting cannot be implemented.
0
Bit9 Reserved - 0
Bit10 Emergency buzzer output
The buzzer tweets at intervals in the emergency evacuation running
state.
0
Bit11 Reserved - 0
Bit12
Shorting stator braking
mode switched over to
controller drive
It enables the function of switching over shorting stator braking
mode to controller drive.
0
Bit13
Mode of shorting stator
braking mode switched
over to controller drive
0
Time setting
If the time of the shorting stator braking mode exceeds 50s,
the controller starts to drive the elevator.
0
1
Speed setting
If the speed is still smaller than the value of F6-48 after 10s in
the shorting stator braking mode, the controller starts to drive
the elevator.
Bit14
Emergency evacuation
exit mode
0
The system exits emergency evacuation when receiving the
door open limit signal from the elevator that arrives at the
destination oor.
0
1
The system exits emergency evacuation when receiving the
door close limit signal from the elevator that arrives at the
destination oor.
Bit15
Shorting stator braking
function
When this function is enabled (Bit15 = 1), the setting of related
parameters becomes effective.
0