- 108 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-46 VIP function selection
Bit0: VIP enabled by hall call (at
VIP īoor)
Bit1: VIP enabled by terminal
Bit8: Number of VIP car calls
limited
0 -
ā
F6-47 Blinking advance time 0.0 to 15.0 1.0 s
ā
F6-48
Emergency evacuation
switching speed
0.010 to 0.630 0.010 m/s
ā
F6-49 Evacuation parking īoor 0 to F6-00 0 -
ā
F6-50 Parallel īoor offset 0 to 40 0 -
ā
F6-50 is used to when the bottom īoors of two elevators in parallel control are different. This parameter supports
direct parallel control without adjusting the top and bottom īoors or shaft-auto-tuning again.
F6-51 Static current 0.00 to 655.00 0 A
ā
Group F7: Test function parameters
F7-00 Car call īoor registered 0 to F6-00 0 -
ā
F7-01 Up call īoor registered 0 to F6-00 0 -
ā
F7-02 Down call īoor registered 0 to F6-00 0 -
ā
These parameters are used to set the destination īoors at elevator commissioning or repairing. They can be
respectively used as the car call button, hall call up button and hall call down button. They remain valid after the
commissioning command is input, and become invalid until they are set to 0 or the system suffers power failure.
F7-03 Random running times 0 to 60000 0 -
ā
F7-04 Hall call forbidden
0: No
1: Yes
0 -
ā
F7-05 Door open forbidden
0: No
1: Yes
0 -
ā
F7-06 Overload function
0: Disabled
1: Enabled
0 -
ā
F7-07 Limit switch forbidden
0: No
1: Yes
0 -
ā
F7-08
Time interval of random
running
0 to 1000 0 s
ā
F7-09
Braking force detection
result
0: No operation
1: Qualiīæed
2: Unqualiīæed
0 -
ā
F7-10
Countdown of braking
force detection period
0 to 1440 1440 min
ā