14
Common faults
Warning code table
If the machine has some common failures, the corresponding phenomena
and solutions are as follows.
Common faults and solutions
No. Phenomena Fault Solution
1
Normal Steady green
2 Charge Flashing green
3
Ground inspection
abnormal
The red light flashes
quickly and the buzzer
sounds for 3-5 times
Place the host back on
the ground
4
Side brush
overload
The green light flashes
quickly, and the
buzzer sounds for 3-5
times
Check the side brush
condition
5
Fan abnormal
The orange light
flashes quickly and the
buzzer sounds for 3-5
times
Check the fan condition
6
Driving wheel
overload
Red and green
flashing, buzzer beeps
for 3-5
Check the condition of
driving wheel
7
Bump switch
abnormal
Notes
If the above method cannot solve the problem, please try the following
actions:
1. Turn off the power of the machine and restart the machine.
2. If the problem cannot be solved by restarting, please send the
machine to the after-sales service center for repair.
The green light flashes
slowly, and the buzzer
sounds for 3-5 times
Check the sensitivity of the
front impact bumper, and
check for foreign objects