EasyManua.ls Logo

Intel 945G - Figure 5 Thermal Solution Performance; Figure 6 Typical 1 U Server Motherboard Component Placement

Intel 945G
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intel
®
945G Express Chipset GMCH Thermal Design Guide
Reference Thermal Solution
Figure 5 Thermal Solution Performance
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
0 50 100 150 200 250 300 350 400 450 500 550 600
Airflow (LFM)
Thermal Characterization Parameter,
Ψ
(°C/W)
Sink-to-Ambient
Case-to-Ambient
Figure 6 Typical 1U Server Motherboard Component Placement
Caution: Heat sink orientation alone does not guarantee that 200 lfm (1.02 m/s) airflow speed will be
achieved. The system integrator should use analytical or experimental means to determine
whether a system design provides adequate airflow speed for a particular GMCH heat sink.
Order #308643 15