26 Intel® RAID Controller RS25DB080 Hardware User’s Guide
Fault Tolerance
Table 10. Fault Tolerance Features
Electrical Characteristics
All power is supplied to the adapter via the PCI Express 3.3V and 12V rail. Necessary
Voltages are provided by onboard switching regulator circuitry operating off of 12V and
3.3V rails.
The following states determine the typical current consumption of the board:
State 1. During BBU fast charge
State 2. During initialization of all RAID 5 logical drives simultaneously
Cache options Write-back or Write-through
Read Ahead
Adaptive Read Ahead
Non Read Ahead
Cache I/O or Direct I/O
Disk Cache
Specification Intel
®
RAID Controller RS25DB080
Specification Intel
®
RAID Controller RS25DB080
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics.
Optional Battery Backup Intel
®
RAID Smart Battery AXXRSBBU9 cache backup
Up to 48 hours of data retention, ‘Gas Gauge’
Drive Replacement Auto detection of failure
Hot-plug
Hot-swap
Drive Rebuild Using Hot Spares Automatic at fail
Dedicated per Array
Global for any array
Auto-resume of initialization or rebuild on reboot
Error Checking and Indication Parity generation and checking, automatic consistency
checking
Patrol reads
Activity and fault LEDs
Multiple retries
Logs in NVRAM, event log, CIM, Smart, Intel
®
RAID
Web Console 2