This indicator appears to indicate the tare function is in operation and
weight displayed is net weight
4. INITIAL SETUP
PLACING THE SCALE
In order to obtain an accurate weighing result, the scale must be placed on a strong and level
surface.
If required, adjust the adjustable feet underneath the scale to obtain a level position. Refer to the
bubble indicator for leveling condition.
INTERNAL SETTING
● Press and hold TARE and press ON/OFF, display shows F1
● Use TARE (next) or M+ (previous) to scroll through the internal setting menu, and press
MODE to enter the setting.
● Use MODE in sub-setting menu to scroll through available options. Press TARE key to
confirm and exit.
● Press ZERO in the function selection screen to SAVE and restart.
CAUTION: BEFORE LEAVING THE INTERNAL SETTING, ALL CHANGES MUST BE SAVED OTHERWISE
THE SCALE WILL STILL FUNCTION UNDER THE OLD SETTING.
F0. Auto zero tracking
This function helps remove unwanted display output within a defined division range when
returning to zero. (Auto Zero Tracking Range = X * 0.5d)
Zero 0 -> Zero 1 -> Zero 2 -> Zero 3 -> Zero 4