What to do if my Intergas Boiler displays sensor fault S1?
- JJodi ClarkSep 3, 2025
If your Intergas Boiler shows a sensor fault S1, check the wiring for any breaks and replace S1 if necessary.
What to do if my Intergas Boiler displays sensor fault S1?
If your Intergas Boiler shows a sensor fault S1, check the wiring for any breaks and replace S1 if necessary.
What to do if there is flame detection fault in Intergas Combi Compact HRE 36/30?
If you're getting a flame detection fault on your Intergas Boiler, try these solutions: * Replace the ignition cable and spark plug cap. * Replace the ignition unit. * Replace the boiler controller.
Why is my Intergas Combi Compact HRE 36/30's CH not reaching the set temperature?
If the central heating (CH) in your Intergas Boiler isn't reaching the set temperature, consider these steps: * Check and adjust the room thermostat setting to 0.1A if it's incorrect. * Increase the CH temperature if it's too low. Check the outside sensor for short circuiting and rectify if needed. * Increase the pump setting or replace the pump if it's not running correctly or the setting is too low. * Ensure there is circulation in the installation; at least 2 or 3 radiators must be open. * Adjust the power if the boiler power hasn't been correctly set for the installation (refer to setting maximum CH power). * De-scale or flush the heat exchanger on the CH side if there's no heat transfer due to lime scale or fouling.
Why does the hot water from my Intergas Combi Compact HRE 36/30 not reach temperature?
If your Intergas Boiler's hot water isn't reaching the desired temperature, consider the following: * Adjust the inlet assembly if the DHW flow is too high. * Set the hot water circuit depending on the desired temperature, if the temperature setting for the water circuit is too low. * Descale or flush the exchanger DHW side if there's no heat transfer due to lime scale or fouling in the heat exchanger DHW side.
Why is the burner resonating in my Intergas Boiler?
If your Intergas Boiler's burner is resonating, consider these potential causes: * The gas supply pressure may be too low. The house pressure switch may be faulty; contact the gas company. * There might be recirculation of combustion gasses; check the gas flue and the air supply. * The gas/air adjustment might not be correctly set; check the setting (refer to gas/air adjustment guidelines).
Why is my Intergas Combi Compact HRE 36/30 not producing hot water (DHW)?
If your Intergas Boiler is not providing hot water, consider the following: * Replace the flow switch if the DHW flow is less than 2.0 l/min. * Check the wiring according to the diagram if there's no current at the flow switch (5V DC). * Replace S3 if the burner isn't firing on DHW. * Refer to the 'burner does not ignite' section if the burner isn't igniting.
Why does my Intergas Combi Compact HRE 36/30 Boiler burner ignite noisily?
If your Intergas Boiler's burner ignites noisily, it could be due to several reasons: * The gas supply pressure might be too high. The house pressure switch may be faulty; contact the gas company. * The ignition electrode gap may be incorrect; check the ignition electrode gap. * The gas/air adjustment may not be correctly set; check the setting (refer to gas/air adjustment guidelines). * There might be a weak spark; the spark gap should be approximately 4.5 mm.
Why is there no heating (CH) in my Intergas Boiler?
If your Intergas Boiler isn't providing heat, consider the following troubleshooting steps: * Replace the thermostat if it's faulty. * Check the wiring against the diagram. * Check the connector X4 if there's no current (24 V). * Replace the faulty manager. * Check the power supply at connector X2. * Replace the faulty pump if it's not running. * Replace sensor S1 or S2 if the burner isn't firing on CH. See fault code. * Refer to the 'burner does not ignite' section if the burner isn't igniting.
Covers regulatory compliance, manual handling safety, and interpretation of warning symbols.
Information on obtaining technical assistance and understanding safety regulations.
Appliance specifications, technical data, product fiche, and identification of boiler components.
Details on overall dimensions, siting requirements, and methods for mounting the boiler.
Procedures for connecting CH, DHW, electrical systems, and flue/condensate.
Steps for filling the system, bleeding air, and verifying combustion parameters.
Adjusting operating modes, DHW comfort, clock, and various boiler parameters.
Identification of fault codes and systematic guidance for resolving common issues.
Instructions for annual servicing, component disassembly, and cleaning.
Essential documentation for ensuring proper installation and recording service history.
| Model | Combi Compact HRE 36/30 |
|---|---|
| Category | Boiler |
| Weight | 37 kg |
| Mounting | Wall-mounted |
| Max working pressure | 3 bar |
| Fuel | Natural Gas |
| Domestic Hot Water Output | 36.0 kW |
| Flue Options | Horizontal or vertical |
| Boiler Type | Combi |