Intergas Heating Ltd 1
Combi Compact
HRE 24/18
(G.C. 47-291-01)
HRE 28/24
(G.C. 47-291-02)
HRE 36/30
(G.C. 47-291-03)
HRE 36/40
(G.C. 47-291-04)
Installation, service
and user instructions
Please read these installation instructions carefully before installing and using
the appliance. Keep these installation instructions with the appliance.
Always act in accordance with the instructions indicated.

Table of Contents

Other manuals for Intergas Combi Compact HRE 36/30

Questions and Answers

  • J
    Jeremy HessSep 3, 2025
    What to do if my Intergas Boiler displays sensor fault S1?
    • J
      Jodi ClarkSep 3, 2025
      If your Intergas Boiler shows a sensor fault S1, check the wiring for any breaks and replace S1 if necessary.
  • J
    Jennifer HerreraSep 1, 2025
    What to do if there is flame detection fault in Intergas Combi Compact HRE 36/30?
    • J
      Joshua Fletcher DDSSep 2, 2025
      If you're getting a flame detection fault on your Intergas Boiler, try these solutions: * Replace the ignition cable and spark plug cap. * Replace the ignition unit. * Replace the boiler controller.
  • E
    ejacksonAug 31, 2025
    Why is my Intergas Combi Compact HRE 36/30's CH not reaching the set temperature?
    • A
      Amanda VargasAug 31, 2025
      If the central heating (CH) in your Intergas Boiler isn't reaching the set temperature, consider these steps: * Check and adjust the room thermostat setting to 0.1A if it's incorrect. * Increase the CH temperature if it's too low. Check the outside sensor for short circuiting and rectify if needed. * Increase the pump setting or replace the pump if it's not running correctly or the setting is too low. * Ensure there is circulation in the installation; at least 2 or 3 radiators must be open. * Adjust the power if the boiler power hasn't been correctly set for the installation (refer to setting maximum CH power). * De-scale or flush the heat exchanger on the CH side if there's no heat transfer due to lime scale or fouling.
  • T
    Teresa PageAug 29, 2025
    Why does the hot water from my Intergas Combi Compact HRE 36/30 not reach temperature?
    • S
      Sean ThompsonAug 29, 2025
      If your Intergas Boiler's hot water isn't reaching the desired temperature, consider the following: * Adjust the inlet assembly if the DHW flow is too high. * Set the hot water circuit depending on the desired temperature, if the temperature setting for the water circuit is too low. * Descale or flush the exchanger DHW side if there's no heat transfer due to lime scale or fouling in the heat exchanger DHW side.
  • M
    megan76Aug 27, 2025
    Why is the burner resonating in my Intergas Boiler?
    • J
      James BarnettAug 27, 2025
      If your Intergas Boiler's burner is resonating, consider these potential causes: * The gas supply pressure may be too low. The house pressure switch may be faulty; contact the gas company. * There might be recirculation of combustion gasses; check the gas flue and the air supply. * The gas/air adjustment might not be correctly set; check the setting (refer to gas/air adjustment guidelines).
  • G
    Gina RichardsonAug 26, 2025
    Why is my Intergas Combi Compact HRE 36/30 not producing hot water (DHW)?
    • K
      Kimberly WhiteAug 26, 2025
      If your Intergas Boiler is not providing hot water, consider the following: * Replace the flow switch if the DHW flow is less than 2.0 l/min. * Check the wiring according to the diagram if there's no current at the flow switch (5V DC). * Replace S3 if the burner isn't firing on DHW. * Refer to the 'burner does not ignite' section if the burner isn't igniting.
  • D
    Daniel OsbornAug 25, 2025
    Why does my Intergas Combi Compact HRE 36/30 Boiler burner ignite noisily?
    • E
      elijahstevensAug 25, 2025
      If your Intergas Boiler's burner ignites noisily, it could be due to several reasons: * The gas supply pressure might be too high. The house pressure switch may be faulty; contact the gas company. * The ignition electrode gap may be incorrect; check the ignition electrode gap. * The gas/air adjustment may not be correctly set; check the setting (refer to gas/air adjustment guidelines). * There might be a weak spark; the spark gap should be approximately 4.5 mm.
  • K
    Kelly GarciaAug 22, 2025
    Why is there no heating (CH) in my Intergas Boiler?
    • R
      Ryan RivasAug 23, 2025
      If your Intergas Boiler isn't providing heat, consider the following troubleshooting steps: * Replace the thermostat if it's faulty. * Check the wiring against the diagram. * Check the connector X4 if there's no current (24 V). * Replace the faulty manager. * Check the power supply at connector X2. * Replace the faulty pump if it's not running. * Replace sensor S1 or S2 if the burner isn't firing on CH. See fault code. * Refer to the 'burner does not ignite' section if the burner isn't igniting.

Summary

Preface and Safety

Introduction and Handling Guidelines

Covers regulatory compliance, manual handling safety, and interpretation of warning symbols.

Service Support and Technical Regulations

Information on obtaining technical assistance and understanding safety regulations.

Technical Data and Components

Appliance specifications, technical data, product fiche, and identification of boiler components.

Installation Procedures

Appliance Dimensions, Location, and Mounting

Details on overall dimensions, siting requirements, and methods for mounting the boiler.

System Connections and Flue Setup

Procedures for connecting CH, DHW, electrical systems, and flue/condensate.

Commissioning, Operation, and Settings

Appliance Filling, Venting, and Combustion Checks

Steps for filling the system, bleeding air, and verifying combustion parameters.

Operation Modes and Parameter Adjustments

Adjusting operating modes, DHW comfort, clock, and various boiler parameters.

Troubleshooting and Maintenance

Fault Diagnosis and Troubleshooting Guide

Identification of fault codes and systematic guidance for resolving common issues.

Boiler Maintenance and Cleaning Procedures

Instructions for annual servicing, component disassembly, and cleaning.

Commissioning Checklist and Service Record

Essential documentation for ensuring proper installation and recording service history.

Intergas Combi Compact HRE 36/30 Specifications

General IconGeneral
ModelCombi Compact HRE 36/30
CategoryBoiler
Weight37 kg
MountingWall-mounted
Max working pressure3 bar
FuelNatural Gas
Domestic Hot Water Output36.0 kW