8.2.4.10 Auto reset
If the Auto reset option is set to Yes, the engineering reset is performed
automatically upon the installer log in.
8.2.4.11 Dis by service
If the Disable when service in option is set to Yes, an engineer reset request is
not issued while the installer is authorized to access the system.
Note: This option is only valid if the installer requires a user authorization. See
“8.2.1 User code required” on page 237.
8.2.4.12 System code
The System code menu allows you to set the system code for engineer reset.
The code can have up to 5 digits.
The default value 0 means that the code is not set. In this case the remote reset
code generation is disabled.
If the code is set, its value and the engineering code value are used in a special
calculation to generate the reset code. See “Engineer reset” on page 102 for
more information.
8.2.4.13 Do reset
The Do reset command is used to perform the engineer reset.
8.2.4.14 Custom text
Use custom text to program a prompt displayed when an engineer reset is
required.
If the custom text is not set, the standard prompt will be displayed as described in
“Engineer reset” on page 102.
Otherwise, the prompts will be the following, depending on a user code display or
warning message: