38  TruVision 12/32 Series IP Camera Configuration Manual 
Figure 14: Audio exception detection window 
 
To define audio exception detection: 
1.  From the menu toolbar, click Configuration > Events > Audio Exception 
Detection. 
2.  Under Audio Input Exception, check Enable to activate the function. 
3.  Under Sudden Change of Sound Intensity check Enable to activate the function. 
4.  Configure the sensitivity and threshold. 
Sensitivity: The smaller the value, the larger the change should be to trigger the 
detection. The range is between 1 and 100.  
Sound Intensity Threshold: This option filters the sound in the environment. The 
louder the environmental sound, the higher the value. Adjust it according to the 
actual environment. The range is between 1 and 100. 
5.  Click Edit to set the arming schedule for the alarm input. See “Motion detection 
alarms” on page 26 for more information. 
6.  Specify the linkage method when an event occurs. Check one or more response 
methods for the system when an audio exception alarm is triggered.