WARNING
Risk of Fire or Electrical Shock
• Disconnectallpowerbeforeinstallingthetimeswitchorconnectedloads.
• Followlocalelectricalandsafetycodes,NationalElectricCode(NEC)andOccupationalSafetyandHealthActCodes(OSHA).
• Morethanonedisconnectorcircuitbreakermayneedtobeturnedofftode-energizeallconductors.
• Ifthepowerdisconnectpointisoutofsight,lockitintheOFFpositionandtagittopreventunexpectedapplicationofpower.
• Thetimeswitchmustbegrounded.
• Donotexceedmaximumcurrentcarryingcapacity.
• Alwaysreplacetheplasticinsulatortoitsoriginalpositionbeforepoweringthetimeswitch.
• Makesurethereisnowireinsulationundertheterminalplateontimeswitchconnector.Firmlytightenterminalscrews.
MODEL PE103/P1403ME
Pool and Spa Two-Speed
Pump Motor Controller
INSTALLATION AND SETUP INSTRUCTIONS
Federal Communications Commission (FCC) Notice for PE103/P1403ME Controller
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and radiates radio frequency energy and, if not installed and used in accordance with
instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference that requires the user to correct at their own expense.
Description
The PE103/P1403ME timer is a programmable pool and spa three-circuit device used for
two-speed pumps and auxiliary equipment. The timer features a programmable Seasonal
Adjust offset that automatically adjusts lter pump ON/OFF schedules according to
season.
At initial power up, the timer is in a setup state that requires users to program the time,
date, year, Daylight Saving Time (DST) option, Seasonal Adjust offset, and low speed
event. Optional high speed and auxiliary circuit ON/OFF events can also be congured
at initial startup. After the setup events are programmed, the timer advances to AUTO
Mode, where relays can be automatically turned ON and OFF according to programmed
events. The relays can also be manually turned ON/OFF by pressing the applicable button
under the active load.
The Seasonal Adjust feature is a user-congured offset (10-minute intervals between 10 and
120 minutes) that increases/decreases the OFF time of the pump. The the timer adds the
offset value to the high and low speed OFF events in March, May, and July. Then the timer
subtracts the offset to the OFF events September, November and January 1st. This ensures
that the pump runs longer in summer swim months and shorter in fall and winter months to
accommodate pool usage.
NOTE: The timer divides the offset equally between the high speed event and the low speed
event. If only the low speed event is used, the complete offset value is added/subtracted to
the low speed event.
NOTE: If you have a single speed pump, be sure to only set the low speed. The high speed
event is not applicable to single speed pumps.
The single speed or two-speed pump and optional auxiliary component wires must be
connected to the applicable terminals on the PE103/P1403ME timer. Refer to Figure 2 to
connect the PE103/P1403ME wiring.
AC IN
NO-4 COM4
+
-
MODE
DAY
HI LO
OFF
EVENT
CLEAR MEM
NO-1 COM1 NO-2 COM2 NO-3 COM3
LOAD LOAD LOAD LOAD
1234
OFF OFF OFF
OFF
AUX
ON/
OFF
ON/
OFF
ON/
OFF
ON/
OFF
ENTER
NEXT
C
L
E
A
R
E
N
T
R
Y
Seasonal Adjust Overview
Connecting the PE103/1403ME Wiring
Figure 1 Front View of the Timer
http://waterheatertimer.org/Digital-control-centers-and-manuals.html#PE103