Brand | Intermatic |
---|---|
Category | Control Systems |
Amperage | 40 A |
Enclosure | NEMA 3R |
Number of Poles | 2 |
Horsepower Rating | 2 HP |
Mounting | Wall Mount |
Operating Temperature | -40 to 158 °F |
Adhere to all installation and servicing instructions provided.
Installation must be performed by a qualified person according to electrical codes.
Install 48 inches from pool edge; use copper conductors only.
Ensure individual components do not exceed maximum ratings.
Refer to NEC Article 680 for grounding, bonding, and wiring of luminaires.
Determine location, run conduits, and ensure box is rigidly supported.
Cut conduits, use reducer bushings, cement, and plug unused openings.
Connect to Equipotential Bonding Grid using the optional external bonding lug.
Pull conductors, connect wires using approved methods, and ground conductors.
Install strain reliefs correctly and make bonding connections.
Check tightness, ensure gasket seating, and close the Junction Box.