SALT CALCULATION FORMULA FOR ALL POOLS
Salt Needed for Startup
Salt Needed for Startup
Salt Needed when
Salt Needed when
(Lbs) (Kgs) Low Salt Detected (Lbs) Low Salt Detected (Kgs)
Water Capacity (Gals) x 0.025 Water Capacity (Liters) x 0.003 Water Capacity (Gals) x 0.0067 Water Capacity (Liters) x 0.0008
SALT TABLE FOR COMMON NON-INTEX POOLS
Salt Needed when
Water Capacity Salt Needed for Startup Low Salt Detected
(CODE “91”)
(Gals)
2000
4000
6000
8000
10000
12000
14000
(Liters)
7500
15000
22500
30000
37500
45500
53000
(Lbs)
50
100
150
200
250
300
350
(Kgs)
20
45
65
90
110
135
160
(Lbs)
10
25
40
55
70
80
95
(Kgs)
5
10
20
25
30
35
45
OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS (WITHOUT CYANURIC ACID
)
Operating Time (hours)
Water Capacity
at different ambient/air temperatures
(Gals)
2000
4000
6000
8000
10000
12000
14000
(Liters)
7500
15000
22500
30000
37500
45500
53000
10 - 19°C
(50 - 66°F)
1
2
3
5
6
7
9
20 - 28 °C
(68 - 82 °F)
1
2
3
5
6
8
9
29 - 36 °C
(84 - 97 °F)
1
3
4
6
7
9
10
CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
Cyanuric Acid Needed for Startup
(Gals)
2000
4000
6000
8000
10000
12000
14000
Water Capacity
(Liters)
7500
15000
22500
30000
37500
45500
53000
(Lbs)
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0.03g/L (30ppm)
(Kgs)
0.23
0.45
0.68
0.90
1.13
1.37
1.59
SAVE THESE INSTRUCTIONS