LED PANEL
TROUBLESHOOTING GUIDE (continued)
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing).
1. Circulation line is blocked.
If your unit has plunger valves, ensure
that they are open.
- Clear your basket and cell of debris and dirt. See “Maintenance”
- Depress the 6-way valve, release all
2. Incorrect inlet and outlet hose
trapped air in the circulation line.
Check the direction of the inlet and the
direction.
3. Scale on the flow sensor.
outlet hose. Reverse the hoses if
necessary. See “Set Up Instructions”.
Clean the flow sensor, paying special
4. Flow sensor cord is loose.
attention to the hinge. See
“Maintenance”.
Plug the flow sensor firmly into the flow
5. Flow sensor failure.
1. Dirt or scale on titanium plates.
2. Low salt level / No salt.
sensor receptacle.
Contact Intex Service Center.
Remove the electrolytic cell for
inspection. Clean it if necessary.
See “Maintenance”.
Add salt. See “Salt & Pool Water
3. Electrolytic cell cord is loose.
4. Possible electrolytic cell failure.
Volumes”.
Ensure that the cell cord is plugged
firmly into the cell housing receptacle.
Contact Intex Service Center. Replace
1. High salt level.
the cell if needed.
Partially drain the pool and refill it with
1. Display and all lights are off - the
system does not power up.
fresh water. See “Salt & Pool Water
Volumes”.
House
hold voltage is too high or too low
(+ 20%). Check the voltage is within the
Range stated on the device housing.
- Contact Intex Service Centre
SAVE THESE INSTRUCTIONS