Intex Pure Spa BUBBLE SB-HWF20
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 27
a. Begin by swapping out the 20-40 water temperature sensor. Disconnect the wire
connector for the sensor and clip on a new replacement. Run the control base on a
spa. Change the 20-40 water temperature sensor if E94 have been solved, then
move on to the next step.
b. Disconnect the flow sensor 20-40 on the PCB. Remove screws that hold the
heating element on the support base. Remove screw of equipotential bonding
system.
c. Pull the pile out and use wrench to disconnect 20-40 water temperature sensor
d. After exposing the heater, remove the 20-40 temperature sensor. It should be the
lower temperature sensor.
2. If the problem still persists after changing the 20-40 sensor, the PCB must be replaced.
Reference the chapter on replacing the PCB for more details.
Remark: If the sensor of 20-40 has problem, it recommend to replace sensor of 50
together.