192
PO
S AVE THESE INSTRUCTIONS
(192PO) SPA ENGLISH 7.5” X 10.3” PANTONE 295U 04/18/2013
English
Site preparation and requirements
• Thespacanbeinstalledindoororoutdoor.Forhouseholduseonly.
• Thespamustbesetuponalevel,atandsmoothsurfacethatiscapableofsupportingthemaximumload
ofthelledspawithfouradultoccupants;weight2500lbs(1136Kg).
• Makesuretheareaisfreeofsharpobjectsunderoraroundthespa.
• Provideadequatedrainagesystemaroundthespatodealwithoverowwaterandsplashes.
• Provideaproperlylocatedpoweroutlettoconnectthespaandalloweasyaccessforperiodictestingofthe
cordmountedGFCI/RCD.
• Makesurethereisenoughclearancearoundthespaforfullaccesstothespaequipmentformaintenance
and/orservice.
• Theareashallfacilitatedrainingpurposesduringlongtermspastorage.
Additional requirements for indoor installation
• Makesuretheoorcansupportthefullweightofthelledspawiththemaximumnumberofoccupants.
Checkwithaqualiedcontractororastructuralengineertoverifythisrequirement.
• Makesuretheooriswaterresistantandnon-slipsurface.Donotinstallthespaoncarpetorother
materials that will be damaged by moisture, condensation.
• Donotinstallthespaindoorsonasecondoorabovenishedlivingspaceduetothepossibilityofwater
and humidity damage.
• Humidityisanaturalsideeffectofindoorspainstallation.Theroomshallbeproperlyventilatedtoallow
moisturetoescape.Installaventilatingsystemtopreventexcesscondensation,moistureintheroom.
Additional requirements for outdoor installation
• Spaownersmayneedtocomplywithlocalorstateslawsrelatingtochildprooffencing,safetybarriers,
lighting,andothersafetyrequirements.Contactyourlocalbuildingcodeenforcementofceforfurther
details.
• Makesurethesurfaceislevel,at,smoothandstrongenoughtosupportthefullweightofthelledspa.
• Donotsetupthespaongrassordirt,asthisincreasestheamountofdebrisenteringthespa,anddamage
thespaoor.
• Donotexposethespatodirectsunlightforextendedperiodoftime.
• Itispossibletoinstallandleavethespaoutsideatatemperaturenotlowerthan39°F(4°C)providedthe
watertemperatureinsidethespaishigherthan39°F(4°C)andthewaterinsidethecirculationsystem,
pump,pipearenotfrozen.Puta“tempbarriermat”betweenthespaoorandthegroundtopreventheat
lossfromthebottomofthespaandtoprovidebetterheatretention.
Page 7
PRODUCT SPECIFICATIONS
SET UP
Maximumseatingcapacity: 4adults
Watercapacity: 210gal(795L)
Inner/outerdiameter: 58/75in(147/191cm)
Height: 28in(71cm)
Bubbleairblower: 0.9HP/110-120V/60Hz
Filterpumpowrate: 400gal/hr(1,514L/hr)
Heaterpower: 1,300Watts/110-120V/60Hz
Temperaturerange: 68ºF–104ºF(20ºC–40ºC)
Temperaturerise: 2-3ºF/hr(1-1.5ºC/hr)
NumberofBubbleJets: 120
Spatubrecommendedworkingairpressure: 0.083bar(1.2psi)
Cord-connectedspawithpump,heater,blowerandcontrolpanel.