SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
Side Entry Whirlpool Tub 28 Part No 1118387
SECTION 4—SAFETY INSPECTION/
TROUBLESHOOTING
NOTE:Everysixmonthsorasnecessaryhaveaqualifiedtechnicianperformathoroughinspection
andservicing.Routinemaintenancewillextendthelifeandefficiencyofyourtub.
Safety Inspection Checklists
Initially
Ensurethatthemaximumwatersupplytemperaturedoesnotexceed115°F.
Ensurethatthemaximumwaterpressuredoesnotexceed65PSI.
Verifythewaterflowtemperaturewithaseparatethermometer.
Visuallyinspectforcracksinthetubsurface.
Ensurethatthedoorhandlelocksthedoorclosed.
Ensurethatthesafetypinproperlyengagesthedoor.
Checkthatalllabelsarepresentandlegible.Replaceifnecessary.
Before Each Use
Disinfectthetub.
Ensurethatthemaximumwatersupplytemperaturedoesnotexceed115°F.
Ensurethatthemaximumwaterpressuredoesnotexceed65PSI.
Visuallyinspectforcracksinthetubsurface.
Ensurethatthedoorhandlelocksthedoorclosed.
Ensurethatthesafetypinproperlyengages
thedoor.
Every 80-150 Baths
Performtheheavydutycleaningprocedureonthetub.RefertoHeavyDutyCleaning
Procedureonpage 30.
Every Six Months
Verifythewaterflowtemperaturewithaseparatethermometer.
Checkthatalllabelsarepresentandlegible.Replaceifnecessary.
CleanRADAvalvetoremovelimedeposits.