8
Cooling
Heating
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U
bent. (Thermistor themometer)
(2) Connecting piping condition : 5 m
2.4 Operation Date
Indoor Outdoor
09K 0.9 to 1.1 53
12K 0.8 to 1.0 72
Outdoor
Fan Mode
Compressor
Revolution(rps)
27/19 35/24 Super High 930rpm
Temp. Condition(
ć
)
Mod el
Standard
Pressure(Mpa)
Indoor Fan
Mode
Indoor Outdoor
09K 2.3 to 2.5 72
12K 2.4 to 2.6 78
Outdoor
Fan Mode
Compressor
Revolution(rps)
20/- 7/6 Super High 930rpm
Temp. Condition(
)
Model
Standard
Pressure(Mpa)
Indoor Fan
Mod e
Specifications
2.5 Noise criteria curve tables for both models
40
42
44
46
48
50
52
54
20 4030 50 60 70 80
Compressor frequency(Hz)
Noise dB(A)
Heating
Cooling
40
30
20
Indoor side noise when blowing
Indoor fan motor rotating speed
Low
Middle
High
12K
09K

Other manuals for INVENTOR EVI-12