Goodrive20 inverters Function Parameters
47
Function
code
Name Detailed instruction of parameters
Default
value
Modify
3:AI3 setting voltage
4:HDI setting voltage
5:Multi-step speed setting voltage
6:PID setting voltage
7:MODBUS communication setting voltage
8~10: Reversed
Note: 100% corresponds to the rated voltage of the motor.
P04.28
Keypad setting
voltage
The function code is the voltage digital set value when the
voltage setting channel is selected as “keypad selection
The setting range:0.0%~100.0%
100.0%
P04.29
Voltage
increasing time
Voltage increasing time is the time when the inverter
accelerates from the output minimum voltage to the output
maximum voltage.
Voltage decreasing time is the time when the inverter
decelerates from the output maximum voltage to the output
minimum voltage.
The setting range:0.0~3600.0s
5.0s
P04.30
Voltage
decreasing
time
5.0s
P04.31
Output
maximum
voltage
Set the upper and low limit of the output voltage.
The setting range of P04.31:P04.32~100.0%
(the rated voltage of the motor)
The setting range of P04.32:0.0%~ P04.31
(the rated voltage of the motor)
100.0%
P04.32
Output
minimum
voltage
0.0%
P04.33
Weakening
coefficient in
constant
power zone
Adjust the output voltage of the inverter in SVPWM mode
when weakening.
Note: Invalid in the constant torque mode.
The setting range of P04.33:1.00~1.30
1.00