INVT GD20-2R2G-4-EU User Manual

INVT GD20-2R2G-4-EU
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INVT GD20-2R2G-4-EU and is the answer not in the manual?

INVT GD20-2R2G-4-EU Specifications

General IconGeneral
ModelGD20-2R2G-4-EU
Power Rating2.2kW
Protection LevelIP20
Storage Temperature-20°C to +60°C
Control ModeV/F
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short circuit
Communication InterfaceModbus
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m

Summary

Safety Precautions

1.3 Safety Guide

General safety guidelines for VFD operation, wiring, and maintenance.

Product Overview

2.4 Product Specifications

Detailed technical specifications of the VFD, including power input and voltage.

2.7 Rated Specifications

Table listing rated specifications for various VFD models, including STO function.

Installation Guide

3.1 Mechanical Installation

Steps and requirements for physically installing the VFD.

3.2 Standard Wiring

Guidelines for standard wiring of the VFD, including main circuit diagrams.

3.2.1 Main Circuit Connection Diagram

Wiring diagrams for the main circuit of the VFD, showing connections for different configurations.

3.2.4 Control Circuit Wiring Diagram

Detailed wiring diagram for the VFD's control circuit.

3.3 STO Function Overview

Explanation of the Safe Torque Off (STO) function and its reference standards.

Keypad Operation Procedure

4.3.1 Modifying VFD Function Codes

Step-by-step guide to modifying VFD function codes through the menu structure.

Function Parameters

P00 Group: Basic Function Group

Parameters related to basic VFD functions like speed control mode and run command channel.

P01 Group: Start-up and Stop Control

Parameters for controlling VFD start-up and stop modes, including DC braking.

P02 Group: Motor 1

Parameters for configuring motor properties such as rated power, frequency, and speed.

P03 Group: Vector Control

Parameters for vector control mode, including speed loop gains and integral times.

P04 Group: SVPWM Control

Parameters for SVPWM control, including V/F curve settings.

P05 Group: Input Terminals

Configuration of input terminals for HDI, digital inputs, and STO function.

P06 Group: Output Terminals

Configuration of output terminals (Y1, Relay RO1, RO2) and polarity selection.

P07 Group: Human-Machine Interface

Parameters related to the keypad interface, including user password and parameter copy.

P07 Group: Human-Machine Interface (Cont.)

Monitoring parameters for VFD fault codes (present, last, etc.).

Fault Tracking

6.2 Fault Solution

General steps for resolving VFD faults and alarms.

6.2.3 Fault Instruction and Solution

A table listing common fault codes, possible causes, and solutions.

Communication Protocol

7.1 Modbus Protocol Overview

Overview of the Modbus protocol, its modes, and network structure.

7.2 VFD Application

How the VFD applies Modbus protocol, focusing on RS485 communication.

7.2.2 RTU Mode

Explanation of the RTU communication mode and frame format.

7.2.3 ASCII Mode

Explanation of the ASCII communication mode and data format.

7.3 Command Code and Communication Data

Illustration of command codes and communication data for RTU mode.

Appendix A Technical Data

Related product manuals